Fluorescence Immunoassay Analyzer, a quantitative instrument that tests quantitative itesms

Views : 5063
Update time : 2015-03-04 20:57:18

1. Introduction:
The Test Device and instrument are for in vitro diagnostic use only.

This instrument is suitable for laboratories with professional testing ability in medical institutions, such as central laboratory, door/emergency laboratory, clinical department and physical examination center. It is equipped with a built-in Test Device Holder. The Test Device Holder will appear through the opening on the front surface of the instrument.

The Power ON/OFF Switch, located on the left of the instrument, which powers the Immunofluorescence Analyzer.The instrument has a built-in printer.This instrument is compact, portable, and easy to operate for fluorescence detection to quantify concentration of various kind of analytes in human blood or urine or feces.This instructions for use introduce the performance and related information of the product and contains graphical procedures for your convenience. 

2 Test Principle
Immunofluorescence Analyzer uses an LED as the Excitation Light Source. The emitted light from the fluorescence microspheres is collected and converted into an electrical signal. The signals are closely related to the amount of fluoresceing dye molecules present on the spot under examination.

After a sample is applied to the Test Device, the Test Device is inserted into Immunofluorescence Analyzer and the concentration of the analyte is calculated by a pre-programmed calibration process. Immunofluorescence Analyzer can only accept Test Devices that are designed specifically for use with this instrument.



3.Basic Specification
Excitation light source: LED
Excitation spectrum: Central wavelength λ0=365nm
Absorption spectrum: Central wavelength λ1=610nm

Test Specimen:Whole blood,Serum Plasma,urine,feces,quality control solution  
Operation environment:Android 5.1.1

Interface: Serial port、USB、Ethernet network
Built-in Printer: Thermal printer
Size: 280X 280 X 170 mm ±5mm
Weight: 2Kg ±100g
Repeatability: CV≤15%
Stability: CV≤15%

4.Operating Environment: Indoor use
Ambient temperature: 5℃~40℃
Relative humidity: 10%-80%(non-condensing)
Atmospheric pressure: 860hPa~1060hPa
Altitude: Up to 2000m
Pollution degree: 2
Voltage: 100-240VAC±10%
Power frequency: 50/60Hz
Input power: 60VA

Related News
Read More >>
Full-auto Chemiluminescence Analyzers unique for Autoimmunity&Allergy Full-auto Chemiluminescence Analyzers unique for Autoimmunity&Allergy
Mar .15.2023
-1st result obtained in 48 minutes
-Up to 218 Tests/Hour
-Built-in 15 inch PC touch screen
-Barcoded reagent, calibrator and control, load in any order at any time Automated real-time inventory monitoring and alarming
-Secondary auto-dilution mode for
Why do we need to detect NAb Why do we need to detect NAb
Jan .26.2021
NAb specifically binds to RBD (receptor binding domain) protein.
It can prevent RBD from binding to ACE2 of host cells, so as to prevent the virus from further infecting the host.
Detection Methodology of Novel Coronavirus Detection Methodology of Novel Coronavirus
Apr .28.2015
The novel coronaviruses belong to the β genus. COVID-19 is an acute respiratory infectious disease. People are generally susceptible. Currently, the patients infected by the nove1 coronavirus are the main source of infection; asymptomatic infected people
Comparison of three detection methods Comparison of three detection methods
Mar .11.2015
According to the research data of SARS, the positive rate of nucleic acid detection in the early 1-5 days is less than 50%, while the antibody detection rate is about 20%, and the antigen detection of positive rate is 90%.